The Cadillac® Sliding Gate Valve

There are two types of Cadillac® steam traps: “Change of State” traps and “Change of Temperature” traps.

The presence of condensate, in steam systems, is undesirable since it prevents efficient heat transfer and encourages corrosion and erosion of steam pipes. It is therefore important to remove condensate on a continuous basis and a steam trap is essentially a self-actuated valve that opens in the presence of condensate and closes in the presence of steam.

There are basically two types of Cadillac® steam traps. There are “Change of State” traps that either mechanically senses the difference in density between condensate and steam, or thermodynamically sense the difference in volume. There are also “Change of Temperature” (thermostatic) traps and they utilize the small difference between condensate discharge and saturation steam temperatures to provide the closing and opening forces on the discharge valve. The “Change of State” traps are represented by the float, bucket, plate orifice, impulse and disc traps. The “Change of Temperature” traps are represented by the bimetallic, bellows and capsule traps. Every trap design has advantages and disadvantages and these have to be evaluated based on performance, cost and maintenance requirements.

Cadillac® Meter has chosen to market the “DE” Steam Trap. It utilizes a bimetallic “D” shaped element that combines both the thermostatic and thermodynamic forces for high condensate discharge capacities and tight shutoff to live steam flow. The “D” shaped element allows for greater linear stem travel, with a single bimetal element, in addition to allowing the use of a smaller steam trap body styles. The stiffness is determined by the overall size of the “D” shape and the thickness and width of the bimetal element. This is important because many of the traps are somewhat cyclic in nature and shock the system, which wears out the trap and could potentially damage other condensate components. When properly sized, the “DE” trap will discharge condensate in a slow, modulating stream rather than discharge in batch mode.

Cadillac® Meter “DE” steam traps are compact and feature an internal strainer. A single model will cover a fairly wide range of applications and its discharge efficiency is unsurpassed. We believe that our traps are one of the best choices available on the market and we hope that you will give us an opportunity to quote you on your requirements.

The Cadillac® Steam Trap Model CS 3A & GM3

Maximum Differential Pressure 30 PSIG

The Cadillac® Steam Trap Model CS 6A & GM6

Maximum Differential Pressure 70 PSIG

The Cadillac® Steam Trap Model CS M10 & GM10

Maximum Differential Pressure 120 PSIG

The Cadillac® Steam Trap Model CS M16 & GM16

Maximum Differential Pressure 200 PSIG


Get in Touch

Central Station Steam Company
Cadillac® Meter
15615 SW 74th Avenue, Bldg. #150
Tigard, OR 97224

Contact us:
Toll-Free: (888)556-3913
Local: (503) 624-6331
Fax: (503)624-6131

Free product quote — No obligation

NAME *
EMAIL *

(*Required Fields)

Copyright © 2012, Cadillac Meter—Central Station Steam